Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The
accuracy is valid for one year at a temperature of +23°C ± 5°C, and at a relative humidity of less than
80 %rF, non-condensing.
DC Voltage
Range
400 mV
4 V
40 V
400 V
600 V
Overload protection: 600 V; Impedance approx.10 MOhm
AC Voltage
Range
400 mV
4 V
40 V
400 V
600 V
Frequency range 50 – 400 Hz; effective average at sinusoidal voltage; overload protection 600 V;
Impedance approx. 10 MOhm
DC Current
Range
400 µA
4000 µA
40 mA
400 mA
Overload protection: 600 V, fuse FF500 mA
AC Current
Range
400 µA
4000 µA
40 mA
400 mA
Overload protection: 600 V, fuse FF500 mA; frequency range 50-400 Hz
42
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
Accuracy
±(1,0% + 5)
±(1,2% + 52)
Accuracy 50-60 Hz
±(1,2% + 10)
±(1,0% + 10)
Accuracy
±(1,5% + 5)
Accuracy
±(1,5% + 5)
Accuracy 400 Hz
±(2,5% + 10)
±(1,2% + 10)