Herunterladen Inhalt Inhalt Diese Seite drucken

Delivery Contents; Intended Use - VOLTCRAFT R-200 Bedienungsanleitung

Milliohmmeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Delivery Content
Multimeter
2 safety measuring leads (red and black)
2 Kelvin measuring leads (red and black)
6 mignon batteries
Plastic case
Operating instructions

Intended Use

- Measuring and displaying electric parameters in the range of excess voltage category CAT III (up to
max. 600V against earth potential, pursuant to EN 61010-1) and all lower categories.
- Measurement of direct and alternating voltages up to a maximum of 600V DC/AC rms (effective)
- Measurement of direct and alternating current between 0 µA and 400 mA
- Measurement of resistances to 40 MΩ using 2-lead measurement procedure
- Measurement of resistances from 0.1 m Ω to 40 Ω using 4-lead measurement procedure (with
Kelvin measuring leads)
- Acoustic continuity check (< 35 ohms) and diode test.
- Capacity measurement up to 40 mF
The measurement functions are selected using the dial switch. Automatic measurement range selection
is active in all measurement ranges (apart from 4-lead low Ohm measurement and continuity test).
The two current measuring ranges are secured against overload with a ceramic high-performance fuse.
The voltage in the measuring circuit may not exceed 600 V.
The measuring instrument must not be operated when it is open, i.e. with an open battery compartment
or when the battery compartment cover is missing. Measurements must not be carried out under
unfavourable ambient conditions.
Adverse ambient conditions include:
- Dust or combustible gases, vapours or solvents,
- Electrical storms or stormy conditions resulting in strong electrostatic fields, etc.
For safety reasons, when measuring only use measuring cables or accessories which are adjusted to
the specifications of the multimeter.
Any use other than that described above will damage the product and may involve other risks, such as
short-circuit, fire, electric shock. Do not change or modify any part of the product.
Read the operating instructions carefully and retain them for later reference.
The safety instructions must be observed!
25

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis