Herunterladen Inhalt Inhalt Diese Seite drucken

Reception; Key Functions; Ptt Transmit Key; Settings - Team Electronic TeCom-Z5 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English

Reception

Upon reception of a signal, the LED (6) lights green.
If the selected frequency is decoded with a CTCSS- / DCS-code, all signals that
are encoded with a different code will be muted. The green LED will light but no
signal will be audible.

KEY FUNCTIONS

PTT Key
The PTT key (9) is located at the left side of the radio. Pressing the PTT key will
switch the radio into transmission mode. The LED (6) will light red.
Multi-Function Keys
The multi function keys PF1 (10) and PF2 (11) are located below the PTT key (9).
They are programmable via the software T-UP19 with one of the following functions:
PF1
display illumination (LAMP)
5-tone selective calling
VOX
LAMP
The background illumination is turned on / off by pressing the programmed PF1 key (10).
5-Tone
The via software programmed 5-tone selective encode is sent by pressing the PF1
key (10).
This function is only available if 5-tone selective calling is enabled and if the actual
channel is set for 5-tone selective calling.
VOX
Starts and stops the VOX function.
Monitor
The monitor function is activated as long as the PF2 key (11) is pressed.
Radio
Start / stop the FM radio by pressing the PF2 key.
Via software one of the two operating modes can be programmed. Either, the radio
frequency can be set in the range between 88 MHz and 107,9 MHz with the Up p /
Down q (3) keys, or the via software programmed radio channels are selected.
22
PF2
monitor
radio (FM)
repeater tone 1450 / 1750 / 2315 Hz
scan
VOX
channels are selected.
In the mode free-selectable-radio-frequency, a scan function is available.
Start the scan function by repeated pushing of the PF2 key (11). During scanning the
symbol SCN. UP appears in the LCD.
Repeater
Send the repeater tone by pressing the PF2 key. These repeater tones are selecta-
ble: 1450 kHz, 1750 kHz and 2315 kHz.
Scan
Start / stop the channel scan function by pressing the PF2 key.
This function is only available if at least two channels are selected for scanning.
Channels of the scan list are marked with the symbol PRI, located to the left of the
battery status symbol.

SETTINGS

The following settings are to be programmed with the software T-UP19. Please use
the software T-UP19 for the radio versions PMR and FreeNet and the software T-
UP19 COM for the radio versions VHF- and UHF-COM.
The following settings can be changed in the software T-UP19 under Edit / Op-
tional Features.
Squelch Level
squelch
settings: 0 - 9; at the value 0, squelch is deactivated, i.e. the channel is comple-
tely open.
Time Out Timer
restricts transmission time
settings: Off / MIN 1 - 7
When activated, transmission is aborted automatically after expiration of the set
time (1 - 7 minutes).
APO
automatic power off
settings: Off, 1 - 15 H
The device is turned off automatically after expiration of the set time.