Installing the appliance

The appliance must be installed and connected by
a qualified installer following these Operating and
installation instructions.
In addition to national legal rules and regulations,
the connection requirements of the local power utility
must also be observed.
After the appliance is installed, you should wait at least
1 hour before starting up the appliance. The oil contained
in the compressor may have been displaced into the
refrigeration system during transport.
Fitting the dust filter
It is imperative that the dust filter supplied with the
appliance is fitted. The dust filter prevents dirt accumu
lating in the motor compartment and thereby reducing
cooling capacity and increasing power consumption.
1. Pull the protective foil off the dust filter.
2. Locate the bottom of the filter in the appliance and
then press in the top so that it snaps into place.
Fitting the ventilation grille in the kick panel
The air circulation for the appliance takes place in the
base. Therefore, the ventilation grille supplied must be
fitted in the kick panel.
H
Cut out the space for the ventilation grille in the
centre of the kick panel.
Dimensions of the cut out required:
Width (W): 540 mm, Height (H): 85 mm
[all dimensions in mm]