Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Delivery; Appliance Dimensions; Optional Accessories - Gaggenau AR401142 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
tinuous flow heaters or water heaters) obtain com-
bustion air from the room in which they are installed
and discharge the exhaust gases into the open
through an exhaust gas system (e.g. a chimney).
With the extractor hood switched on, air is extracted
from the kitchen and the adjacent rooms. Without an
adequate supply of air, the air pressure falls below
atmospheric pressure. Toxic gases from the flue or
the extraction shaft are sucked back into the living
space.
Always ensure adequate fresh air in the room if
the appliance is being operated in exhaust air
mode at the same time as a room-air-dependent
heat-producing appliance is being operated.
It is only possible to safely operate the appliance
if the pressure in the room in which the heating
appliance is installed does not drop more than
4 Pa (0.04 mbar) below atmospheric pressure.
This can be achieved whenever the air needed for
combustion is able to enter through openings that
cannot be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or by other tech-
nical means. An incoming/exhaust air wall box
alone does not ensure compliance with the limit.
In any case, consult your responsible chimney
sweep. They are able to assess the house's entire
ventilation setup and will suggest the suitable
ventilation measures to you.
Risk of poisoning from flue gases being drawn back
in.
Do not emit the exhaust air into a smoke or ex-
haust gas flue that is in operation.
Do not emit the exhaust air into a shaft that is
used to ventilate installation rooms for heat-produ-
cing appliances.
If the exhaust air is to be conveyed into a smoke
or exhaust gas flue, you must obtain the consent
of the heating engineer responsible.
Risk of poisoning from flue gases being drawn back
in.
If an extractor hood with an open-flued heat pro-
duction source is installed, the power supply for
the extractor hood must be provided with a suit-
able safety switch.
WARNING ‒ Risk of suffocation!
Children may put packaging material over their
heads or wrap themselves up in it and suffocate.
Keep packaging material away from children.
Do not let children play with packaging material.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appli-
ance from the electricity supply. The appliance must
only be connected to a protective contact socket
that has been correctly installed.
The mains plug for the mains power cable must
be easily accessible after the appliance is in-
stalled.
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical
installation according to the conditions of over-
voltage category III and according to the installa-
tion regulations.
The permanent electrical installation must only be
wired by a professional electrician. We recom-
mend installing a residual-current circuit breaker
(RCCB) in the appliance's power supply circuit.
An ingress of moisture may cause an electric shock.
Ensure that the plug connections for the electric
cable are located within the building.
Ensure that the fixing plate is sealed onto the out-
side wall using suitable material.
WARNING ‒ Risk of injury!
Changes to the electrical or mechanical assembly
are dangerous and may lead to malfunctions.
Do not make any changes to the electrical or
mechanical assembly.
Components inside the appliance may have sharp
edges.
Wear protective gloves.

Scope of delivery

After unpacking all parts, check for any damage in
transit and completeness of the delivery.
→ Fig.
1

Appliance dimensions

You will find the dimensions of the appliance here
→ Fig.
2

Optional accessories

This is where you can find an overview of the op-
tional accessories for different installation variants.
Pipe adapter from a diameter of 200 mm to 150 or
125 mm.
Order number
AD702042
¡
→ Fig.
3
Adapting to a diameter of 150 or 125 mm by sawing
off the diameter not required
Telescopic wall outlet with a diameter of 200 mm,
with integrated back-flow flap
Order number
AD702052
¡
→ Fig.
4
Air collector box for flat ducts
Order number
AD854048
¡
→ Fig.
5
Air collector box for round ducts
Order number
AD754048
¡
→ Fig.
6
Air collector box for flat ducts
Order number
AD704050
¡
→ Fig.
7
Information about the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
Sharp-edged components inside the appliance may
damage the connecting cable.
Do not kink or trap the connecting cable.
The connection data can be found on the rating
¡
plate.
7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

400 serieAd854048Ad704050Ad754048Ar403122

Inhaltsverzeichnis