Commissioning
This section describes how to commission the device. This
includes the connection of the device, the logging onto the config-
uration manager and an initial configuration.
Default Settings when the Equipment is Supplied
–
Access data for the Configuration Manager :
User name: admin
i
Password: admin (password before firmware version 14A:
i
ip6000)
–
Network settings:
DCHP enabled
i
–
Network addresses (If no DHCP server is available in the net-
work):
IP address: 192.168.0.1
i
Network mask: 255.255.255.0
i
Connecting the IP DECT Server
Requirements
–
Network cable
Insert one of the network cable's plugs in the RJ45 socket on
1.
the front of the device.
Insert the plug on the other end of the network cable into a
2.
network socket.
Connect the device to a mains socket.
3.
The LED on the front cover flashes red followed by a
steady green if the IP DECT server has been configured.
Opening the Configuration Manager
Requirements
–
Existing network connection between the PC and the IP
DECT server
–
Knowledge of the IP DECT server's IP address
Note:
If a DHCP server is set up in the local network, the IP DECT server
will get its IP address from this DHCP server. You can determine
the IP addresses either via the DHCP server and the IP DECT
server's MAC address or via UPnP.
If no DHCP server has been set up, the static IP address
192.168.0.1 and the network mask 255.255.255.0 are used
instead after a waiting time of approx. 1.5 minutes.
24
COMfortel WS-650 IP - Setup and Quick Guide V03 07/2016
Commissioning