Preparation
This section describes the preparations required before commis-
sioning the device.
Rack-Mounting the IP DECT Server
The COMfortel WS-650 IP is designed to be mounted in a 19"
rack.
Requirements
–
Tools and materials:
The support bracket and screws included in the scope of
i
delivery
Screwdriver
i
–
Connections close to the mounting location:
Mains power socket with protective earth
i
Network socket
i
Warning: Liquid that penetrates the casing can cause
life-threatening electric shocks or can damage or destroy
the device.
Only operate the device in closed, dry rooms.
When cleaning the casing, make sure that no liquid enters the
casing.
Caution: Overheating can damage or even destroy the
device.
Note the values given for ambient temperature and humidity
in the technical data.
Do not expose the device to direct sunlight.
Ensure that heat produced by the device can be adequately
vented into the environment. Do not install the system in a
cabinet without adequate air circulation.
Caution: Mechanical stress and electro-magnetic fields
can result in the damage or destruction of the device or
impairment of its functions.
Avoid mechanical loads (e.g. vibrations).
Protect the device from dirt, excessive dust, condensation,
caustic liquids, and steam.
Use 4 screws to attach the support brackets to the casing.
1.
22
COMfortel WS-650 IP - Setup and Quick Guide V03 07/2016
Preparation