Commissioning
Enter the current password in the Current password entry
2.
field.
Enter a new user name in the New username entry field.
3.
Enter a new password in the New password entry field.
4.
Then enter the new password again in the New password
5.
again entry field.
Click Save > OK.
6.
SIP Settings
Open the Configuration > SIP page.
1.
Under General, enter the number of the SIP port in the Local
2.
port entry field.
Note: The standard port 5060 is already set up. Configure the
port according to the port configuration in the PBX.
Enter the PBX's IP address in the Default domain entry
3.
field.
Select the priority of codecs in the Codec priority list fields.
4.
Note: During operation on Auerswald PBXs, we recommend the
following codec priority configuration:
1: PCMA/8000 (G.711 A-law)
2-6: None
During operation on PBXs from other manufacturers, configure
the codec priority according to the available codecs.
Click Save > OK.
5.
Configuring a DECT Handset
Requirements
–
Knowledge of the handset data:
IPEI (available in the handset under Menu > Status >
i
General information)
Internal number, password (registered in the PBX)
i
Open the Users page.
1.
Click New.
2.
Under DECT, enter the DECT handset's IPEI in the IPEI en-
3.
try field. Format: 12-digit xxxxx xxxxxxx
26