Minisphere 100/130
tially the errors that occur with a duration of two 2 seconds each.
If an error has been fixed, it is no longer displayed automatically.
Fig. 17: SC410 Errors
2.2.9.
Error code description
Error
Component
code
F00
Clutch / compres-
Defective or not properly
sor
hooked up
F01
Operating
Operating voltage
voltage
< 10V... 16V)
F02
System
No 12V system
recognized
Reason
Remedy
– Check wiring harness
– Replace pressure
switch
– Replace compressor
– Replace ECU
– Check wiring harness
– Replace ECU
– Check wiring harness
– Replace ECU
Control elements and display
Error
Component
code
F03
System
No basic or standard
system recognized
F04
Inside tempe-
Short circuit to plus pole – Check wiring harness
rature sensor
F05
Inside tempe-
Short circuit to ground
rature sensor
F06
Channel tempe-
Short circuit to plus pole – Check wiring harness
rature sensor
F07
Channel tempe-
Short circuit to ground
rature sensor
F08
Memory module
No access to EEPROM /
no data consistency
F09
Water valve
Water valve cannot be
calibrated or brought into
the correct position.
F10
Clutch
Repeated occurrence of
the clutch error
Reason
Remedy
– Replace ECU
– Replace sensor
– Replace ECU
– Check wiring harness
– Replace sensor
– Replace ECU
– Replace sensor
– Replace ECU
– Check wiring harness
– Replace sensor
– Replace ECU
– Replace ECU
– Water valve / sensor
– Genuine parts used?
– Replace acc. to spare
parts list
– See remedy F00
29