9. Defects - causes - remedies
All incidents hereafter mentioned give rise to :
• The resting of the SBM relay (unavailable trans-
fer)
• The activation of the SSM relay (failure transfer)
when the maximum quantity of one type of
defect is reached over a 24 hours range.
• Lightening of a red LED and the defect code dis-
play.
If the defect is major, the action of an
after-sales technician is required.
S S I I G G N N A A L L L L I I N N G G
Reaction
C C O O D D E E
time before
D D E E F F E E C C T T
converter
stop
E00
1mn
E01
1mn
≤5s
E04
(E32)
≤5s
E05
(E33)
≤5s
E06
E07
3s
E10
3s
E20
3s
E23
immediate
≤5s
E25
E26
immediate
E30 E31
3s
E36
1,5s
E42
5s
E50
immediate
1
State of the relay if the number of failure > than the allowed number of failure.
Restart of the pump after a detection of defects :
1st case - T T h h e e p p u u m m p p h h a a s s r r e e a a c c h h e e d d t t h h e e m m a a x x i i q q u u a a n n t t i i t t y y o o f f d d e e f f e e c c t t s s (from 1 to 6, according to the significance) of the same
defect type over a 24 sliding hours period. In this case, the SSM relay is activated and the SBM relay is at rest. The pump
can be restarted by pressing on the encoder (long push-on > 2s) or by switching off the supply and by restoring it.
2nd case - • T T h h e e p p u u m m p p h h a a s s n n ' ' t t r r e e a a c c h h e e d d t t h h e e m m a a x x i i q q u u a a n n t t i i t t y y o o f f d d e e f f e e c c t t s s . .
In this case, the SSM and SBM relays are at rest. Only a switch off and a restoration of the supply allow the restart.
For both cases, it is necessary to proceed at first to the deletion of the defect. In case of intervention on the pump,
switch off the supply beforehand.
34
B B E E H H A A V V I I O O U U R R O O F F T T H H E E C C O O N N V V E E R R T T E E R R
STATE OF RELAYS
Waiting
Max qty
time
of defects
SBM
before
over 24
restart
hours
rest
1mn
6
rest
1mn
6
rest
5s
6
2
rest
5s
6
2
rest
5s
6
2
resr
immediate
no
limite
rest
no
1
restart
rest
5mn
6
2
rest
5mn
6
2
rest
no
1
restart
rest
5mn
6
2
rest
5mn
6
2
rest
no
1
restart
rest
no
1
restart
rest
5mn
no
limite
I I N N C C I I D D E E N N T T S S / / P P O O S S S S I I B B L L E E C C A A U U S S E E S S
SSM
active
Pump is no more primed or runs
1
dry
active
Load of the pump is excessive,
1
pump is defective, or the pump
is obstructed by particles
active
The converter supply is in under-
1
voltage
active
The converter supply is in over-
1
voltage
active
A supply phase is missing
1
active
The converter runs like a
1
generator.
active
The pump is locked
1
active
The motor heats
1
Water temperature
> +50°C
Ambient temperature
> +40 °C
The converter or the motor is in
active
1
short-circuit.
active
Missing phase(s) between motor
1
and converter
active
The thermal sensor of the motor is
1
defective or has a wrong connec-
tion
active
The converter heats
1
Water temperature
> +50°C
Ambient temperature
> +40 °C
active
Internal problem of converter
1
active
The cable of the sensor (4-20mA)
1
is cut
PLR communication defect
active
1
R R E E P P A A I I R R I I N N G G
Prime the pump once again by filling it
(see chapter 8-3)
Density and/or viscosity of the conveyed fluid are too
big. Dismantle the pump and replace the defective
components or clean them
Check voltage at the converter terminals.
Minimum 400V -10%
Check voltage at the converter terminals
Maximum 400V +10%
Check the supply
The pump veers, check the tightness of the non-
return valve
Dismantle the pump, clean it and replace the defecti-
ve parts
The motor is foreseen to run at :
maximum water temperature of + 50°C
maximum ambient temperature of + 40°C
Dismantle the motor-converter of the pump, check it
or replace it
Check the connection between motor and converter.
Dismantle the motor-converter, check it or replace it
Dismantle the motor-converter of the pump, check it
or replace it
Check the bypass, check the operating conditions
Check the bypass
The converter is foreseen to run at :
maximum water temperature of + 50°C
maximum ambient temperature of + 40°C
Call on after-sales technician
Check the correct supply and the cable connection of
the sensor
Failure of the interface or the cable. Check or replace