Put the charger in set-up mode, as described earlier.
A '0' will appear in the display screen. By way of pressing on the 'mode' button it is
possible to switch between the green and the red led. Adjust the charger as per the
green led (= factory setting).
After this wait for 10 seconds. A number will now appear in the display screen which
indicates the charging program. By way of repeatedly pressing the 'mode' button it is
possible to enter the correct charging program which corresponds to the battery type.
Battery type
GEL
WET (factory setting)
SEMI TRACTION, SPIRAL
FULL-TRACTION
CALCIUM
AGM
After this wait for 10 seconds.
A 't' will appear in the display screen. Now it is possible to determine if the optional
temperature sensor has been connected. By way of pressing the 'mode' button it is once
again possible to switch between the green and red led. If the temperature sensor is
present, allow the green led to light up.
Temperature sensor
present
Temperature sensor
isn't present
(factory setting)