4. Technical data

Power supply: .......................................................
...............1 x 9 V block battery; type 6LR61 / 6F22
Detection depth for wood, metal: ...... max. 19 mm
Detection depth for ferrous metals: ... max. 50 mm
Detection depth for copper:............... max. 38 mm
Detection depth for live cables: ......... max. 50 mm

5. Before starting the equipment

Inserting batteries (Fig. 1)
Turn off the equipment using the ON/OFF
button (4)
Open the battery compartment cover (5).
Connect the battery (a) to the plug, ensuring
that you fit it the right way round.
Insert the battery in the battery compartment
Close the battery compartment cover (5)
again, making sure that it locks securely

6. Operation

Danger!
The tool cannot provide a one hundred per-
cent guarantee of safety. In order to eliminate
possible dangers it is necessary to take
precautions by checking other sources of in-
formation such as building plans, photos from
the time of construction, etc., before starting
any drilling, sawing or routing work in walls,
ceilings or floors.
Whenever any material is detected in the wall,
a check must always be made as to whether
the material concerned is a live cable.
Work is only allowed to be performed in the
area of electric cables if the power supply has
been disconnected. If in doubt, contact an
electrician or personnel with similar qualifica-
tions.
Beams and supports are generally spaced
at regular intervals behind walls or ceilings.
Electric cables and water pipes on the other
hand, for example, are spaced irregularly.
Check the spacing of objects before you start
working on walls or ceilings.
GB
It is possible for measurement errors to occur
depending on the characteristics of the sur-
face involved.
The identified object may actually be wider
or narrower than shown on the display. This
varies according to the depth.

6.1 ON/OFF switch

Press the ON/OFF button (4) to switch the equip-
ment on and off .
The equipment switches off automatically after 60
seconds without an entry being made.
6.2 Functions
The selection buttons (3) provide you with four
diff erent functions to select from:
STUD:
For metallic and non-metallic materials (wood,
metal, etc.)
Detection depth for wood:
Detection depth for metal:
METAL:
For ferrous materials and copper piping
Detection depth for ferrous metals:
max. 50 mm
Detection depth for copper:
DEEP:
For copper piping, metal, wood
Detection depth for copper:
Detection depth for metal:
Detection depth for wood:
AC:
For live cables
Detection depth:
6.3 Calibration
The equipment needs to be calibrated for the
characteristics of the search area before each
measurement (wall, fl oor or ceiling). Calibration
needs to be repeated every 60 seconds in order
to reduce the occurrence of measuring errors.
Switch on the equipment (see 6.1) and select
the function you require (see 6.2).
Hold the equipment against the surface with
the back against the surface
Select an area where there is probably less
likelihood of finding the material you are trying
to locate
Press the detection button (2) and keep it
pressed
- 16 -
max. 19 mm
max. 19 mm
max. 24 mm
max. 38 mm
max. 38 mm
max. 19 mm
max. 50 mm