3. SHUTDOWN AT THE END OF THE WORK
SHORT DURATION SHUTDOWN
1 -
Decrease the material pressure of air regulator (D) until reading 0 bar / 0 psi on gauge (E).
2 -
Trigger the gun to depressurize the system.
3 -
Remove the nozzle of the spray gun and soak it into solvent.
LONG DURATION SHUTDOWN
1 -
Decrease the material pressure of air regulator (D) until reading 1 bar / 14.503 psi on gauge (E).
2 -
Remove the nozzle from the spray gun and soak it into solvent.
3 -
Open the drain valve. The pump must operate at low speed. If the speed is too high, decrease
the pump air pressure (D).
4 -
Remove the suction rod and the drain rod from the material container and immerse it in a
solvent-filled container. Take all the appropriate precautions in the presence of flammable
solvents.
5 -
When the solvent flows out clear and clean, close the drain valve.
6 -
Point the spray gun towards the material container and press the gun trigger. When the solvent
flows out, point the gun towards the recovery container.
7 -
When the solvent flows out regularly, release the spray gun trigger.
Nota : If the pump is a intensive™ one, release the spray gun trigger when the pump
8 -
Fully unscrew the air regulator (D) and shut off the main compressed air valve (valve H).
9 -
Trigger the spray gun trigger to decompress the hoses. Therefore, the pump and the hose
remain filled with solvent at the atmospheric pressure.

4. SAFETY DEVICE

Guards (air motor cover, coupling shields, housings ...) have been designed for safe use
The manufacturer will not be held responsible for bodily injury or failure and / or damage
to property due to removal or partial removal of the guards
A relief-valve (setting : 6.5 bar / 94 psi) is fitted on the pump air motor - thus protecting this one from an
overpressure which could damage it.
KREMLIN REXSON
piston is in a low position. To prevent from damaging the seals when starting
once again the pump, the piston must be immersed into solvent.
of the equipment.