Herunterladen Inhalt Inhalt Diese Seite drucken

Operation Via Dip Switches; Dmx-Controlled Operation; Addressing - EuroLite MD-3030 DMX Safety Rotary Motor Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation via DIP Switches:

Manual Mode: Rotation Direction and Speed
In order to select Manual Mode, set DIP- switch 10 to OFF.
Rotation speed can be selected via DIP-switch 1: 0.5 RPM = ON; 1 RPM = OFF.
Rotation direction can be selected via DIP-switch 2: clockwise = OFF; counterclockwise = ON.
DIP-switches 3 to 9 have no function.
Master-Slave
In order to select the Master unit, set DIP-switch 10 to ON.
Set DIP-switch 10 to OFF on the Slave devices.

DMX-controlled operation:

You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
For DMX-controlled operation set DIP Switch 10 to ON.
Use DIP Switches 1 to 9 to set the desired DMX addresses.

Addressing

Each device occupies 1 channel. To ensure that the control signals are properly directed to each device, the
device requires addressing. This is to be adjusted for every single device by changing the DIP-switches as
set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Controlling:
After having addressed all devices, you may now start operating these via your controller.
Note:
The modes of DMX 512 data are shown via the DMX indicator.
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received, the control LED will flash.
If there is no data received at the DMX-input, the control LED lights up permanently.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are not properly connected with the input connector.
18/19
00066238.DOC, Version 1.3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

50301530

Inhaltsverzeichnis