Before each fault elimination:
− switch off device
− wait for standstill of the beater
− pull out power plug
After each fault clearance, put into operation and recheck all security installations.
Problem
Motor does not start.
Unusual vibrations
Device starts but blocks under
slight load and cuts off auto-
matically.
Typ / Model
Year of construction
Motor power P
1
MotorMotor
Speed n
0
(with speed control)
Beater diameter
Beater chuck
Beater length
Hand/arm vibration on the handle
(according to EN 1033/DIN 45675)
Measuring uncerntainty K
Volume of the material to be mixed
Weight
Measured sound power level L
(as per EN ISO 4871)
Measured sound pressure level L
(as per EN ISO 4871)
Measuring uncerntainty K
Safety class
Protection class
16
P
P
Possible cause
⇒ No power supply (power failure)
⇒ Mains cable defective.
⇒ Motor or switch defect
⇒ Beater defective.
⇒ Chuck defective.
⇒ Non-intended material to be mixed.
⇒ Extension cable too long, or cross-
section too small.
⇒ Socket too far away from main connec-
tion, and cross-section of connection
lead too small.
T
T
WA
PA
o
s
s
i
b
l
e
f
a
u
l
t
s
o
s
s
i
b
l
e
f
a
u
l
t
s
Remedy
⇒ Check fuses (10 A)
⇒ Exchange defect cable, respectively check ex-
tension cable, (by electrician)
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
⇒ Replace the beater.
⇒ To correct the problem, refer to the manufacturer
or other approved service centre.
⇒ Incorrect processing. Follow the processing in-
structions from the supplier.
⇒ Extension cable at least 1,5 mm2 , maximum 25
m long.
⇒ Cross- section of at least 2,5 mm2 in longer
cables.
e
c
h
n
i
c
a
l
d
a
t
a
e
c
h
n
i
c
a
l
d
a
t
a
RW 1800 Twin
See last page
AC-motor 230 V ~ 50 Hz
1. speed: 0 - 450 min
2. speed: 0 - 790 min
Quick Adapter
Ca. 570 mm
a
= < 2,90 m/s²
h
Mixing of lime water
101 dB (A)
II /
Never use defect lead
1800 W
-1
-1
220 mm
1,5 m/s²
< 90 Liter
7,5 kg
90 dB (A)
3 dB (A)
double insulated
IP 20