Instruction for using the agitator
Hold the device with both hands during mixing.
Do not reach in the running beater (rotating beater).
Avoid splashing. Work with low speed when immersing
the beater in the material to be mixed or pulling it out.
Only use beaters recommended by the manufacturer.
Pay attention the max. diameter:Ø 140 mm - RL 1400.
The supplied mortar beater is suitable for materials with
tough and tenacious consistency: e.g. mortar, knifing fillers,
cement, plaster, lime, concrete, flooring plaster, etc.
Increase the speed during the mixing process. Immerse the
beater through the material to be mixed until it is thoroughly
mixed. Follow the processing instructions from the suppli-
ers.
Do not work with low speed in continuous mode. This
may result in overloading/overheating the motor as no suffi-
cient cooling can be generated.
The following beater attachments can be used to mix
other materials:
Spiral beater (15)
for mixing materials with tacky and tenacious consistency:
e.g. adhesive mortar, tile and construction adhesives,
ready-mixed plaster, knifing fillers, flooring plaster, etc.
Disk beater (14)
For liquid and levelling materials: e.g. varnishes, paints,
levelling compounds, pastes, etc.
M
a
i
n
t
M
a
i
n
t
Before each maintenance and cleaning
work:
- switch off device
- wait for standstill of the beater
- pull out power plug
Use only original parts. Other parts can result in unexpected
damages and injuries.
Maintenance and repair work beyond this is only allowed to be
carried out by the manufacturer or authorized service staff.
Store unused equipment in a dry, locked place out of the reach
of children.
Observe the following to maintain the operability of the
machine:
Keep vent slits clean and free from obstructions.
Remove dust and dirt using a cloth or a soft brush.
Do not clean the machine with running water or high-
pressure cleaners.
Do not use solvents for the synthetic parts (petrol, alcohol,
etc.) as these can damage the synthetic parts.
Check that the handles are properly secured.
Clean the beater.
i
t
h
t
h
e
a
g
i
t
a
t
o
r
w
i
t
h
t
h
e
a
g
i
t
a
t
o
r
e
n
a
n
c
e
a
n
d
C
a
r
e
e
n
a
n
c
e
a
n
d
C
a
r
e
The agitator is equipped with carbon brushes. Have the
carbon brushes be replaced by the customer service if they
are worn
Regularly check the beater for damages for your own
safety. Immediately replace any damaged beater.
Check the shaft on a regular basis. An agitator with defec-
tive shaft must no longer be used. Have the device be repaired
by the customer service.
Replacing the carbon brushes
Replace the carbon brushes once they have been worn down
to approx. 4 mm.
Remove the carbon brush cover (9) on the side of the
motor cover by turning it counterclockwise using a suitable
screw driver.
Remove the carbon brushes; note the position of the spring
retention.
Insert the new carbon brushes (10) observing the correct
position of the spring retention.
Replace the carbon brushes only in pairs.
Screw in the carbon brush cover again.
S
S
Pull out power plug
 Store unused equipment in a dry, locked place out of the
reach of children.
 Before a longer period of storage carry out the following to
extend the machine's service life and ensure an easy operat-
ing:
− thoroughly clean the device
G
G
Please observe the enclosed terms of guarantee.
t
o
r
a
g
e
t
o
r
a
g
e
u
a
r
a
n
t
e
e
u
a
r
a
n
t
e
e
15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis