Tabelle 2-8. Systemmeldungen
Meldung
Invalid NVRAM
configuration, resource
re-allocated
Invalid SCSI configuration
SCSI cable detected on
connector SCSIB of the
SCSI backplane, daughter
card not present
Keyboard controller
failure
Keyboard clock line
failure
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
Memory address line
failure at address, read
value expecting value
Memory double word logic
failure at address, read
value expecting value
Memory high address line
failure at start address
to end address
Memory high data line
failure at start address
to end address
Memory odd/even logic
failure at start address
to end address
Memory write/read failure
at address, read value
expecting value
(Fortsetzung)
Ursachen
Systemkonfigurationsdaten
wurden ignoriert.
Es ist ein SCSI-Kabel an den
Kanal-B-Anschluss der SCSI-
Rückwandplatine angeschlossen;
die SCSI-Rückwandplatinen-
Tochterkarte ist nicht installiert.
Fehlerhafter Tastatur-Controller;
fehlerhafte Systemplatine.
Ein Tastaturkabel ist lose oder
nicht ordnungsgemäß angeschlossen;
fehlerhafte Tastatur; fehlerhafter
Tastatur-Controller.
Fehlerhafte oder nicht
ordnungsgemäß installierte
Speichermodule.
Korrekturmaßnahmen
Überprüfen Sie die Konfigurationsein-
stellungen im System-Setup. Weitere
Informationen finden Sie unter
„System-Setup-Programm verwenden"
im Benutzerhandbuch.
Diese Meldung ist für das hier
erläuterte System nicht relevant.
Siehe „Weitere Hilfe".
Siehe „Störungen bei einer Tastatur
beheben" in „Störungen beim System
beheben".
Siehe „Störungen bei einem
Systemspeicher beheben" in
„Störungen beim System beheben".
Anzeigen, Codes und Meldungen