4.10 Installing inside an open fireplace

The Jøtul I 520 is designed to be placed inside a pre-existing, code-compliant masonry fireplace. The fireplace must satisfy the
requirements regarding installation against combustible materials. It is important that the convection air openings are sufficiently
large (500 / 750 cm 2 ) to utilize the heat emission from the product.
There are several options for installation in hearths/open fireplaces. Here are three options:
1) Placed in a corner with plenty of space
The illustration shows the Jøtul I 520 FR (glass in the door and on the right-hand side). In this example, a sheet metal grid is used
(optional - item no. 50045748) to fill the space between the insert and the fireplace.
Fig. 27
A
A
The sheet metal grid (A) must be cut to fit the fireplace. See separate manual for instructions on how to fit the sheet metal grids.