Herunterladen Inhalt Inhalt Diese Seite drucken

Connection With The Mains; Operation; Stand-Alone Operation; Master/Slave Operation - EuroLite LED TMH-X12 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

With the power switch, you can switch the device on and off.
After you connected the effect to the mains, the EUROLITE LED TMH-X12 starts running. During the Reset,
the motors are trimmed and the device is ready for use afterwards.

Stand-alone operation

In the Stand-alone mode, the LED TMH-X12 can be used without controller.
Disconnect the LED TMH-X12 from the controller and call the internal program. Please refer to the
instructions under Control Board.

Master/Slave operation

The master/slave operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the device you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can
be used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a DMX cable. Connect the DMX
OUT-jack with the DMX IN-plug of the next device.
Set the desired Master-mode - „Run mode" - for the master-device, as described in chapter Control Board.
Set the DMX address 001 for all slave-devices.
International
L
N
27/34