Herunterladen Inhalt Inhalt Diese Seite drucken

Yamaha M7CL-32 Bedienungsanleitung Seite 288

M7cl
Vorschau ausblenden Andere Handbücher für M7CL-32:
Inhaltsverzeichnis

Werbung

MIDI-Datenformat
4.8 Function call – Channe –
4.8.1
Pair ON/OFF Trigger Format (Parameter change)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00010001 11
DATA
00000000 00
CATEGORY
FUNCTION
01000011 "C"
NAME
01101000 "h"
01101100 "l"
01010000 "P"
01101001 "i"
01110010 "r"
01000011 "C"
01110000 "p"
MODULE NAME 0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
DATA
0sssssss ss
0sssssss ss
0ddddddd dd
0ddddddd dd
EOX
11110111 F7
4.8.2
Module Name
MODULE NAME
Pair On (with Copy)
Pair On (with Reset Both)
Pair Off
*1) 0:CH1–47:CH48
256:MIX 1– 271:MIX 16
512:MATRIX 1–519:MATRIX 8
288
M7CL – Bedienungsanleitung
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
M7CL
OTHER DATA
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
(ASCII CODE)
Source Channel Number H *1)
Source Channel Number L *1)
Destination Channel Number H *1)
Destination Channel Number L *1)
End of exclusive
"PAIRONCP"
"PAIRONRS"
"PAIROFF_"
4.9
Level Meter Data
4.9.1
Format (Parameter change)
When transmission is enabled by receiving Request for Level Meter, the
corresponding metering data will be sent in every 50 millisecond for 10 seconds.
If metering information is expected to be continuously sent, Request is needed
to be sent in at least every 10 seconds.
Receive
The data will be echoed when [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving Request, the corresponding metering
data will be sent in constant interval for a given period of time (The interval and
time will vary depending on devices). When rebooted or port setting is changed,
the transmission will be disabled.
When [Parameter change ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
Digital mixer
GROUP ID
00111110 3E
M7CL
MODEL ID
00010001 11
REMOTE LEVEL METER
DATA
00100001 21
CATEGORY
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Data1
0ddddddd dd
:
:
End of exclusive
EOX
11110111 F7
4.9.2
Format (Parameter request)
Receive
Data will be received when [Parameter change Rx] is on and the Device number
of both [Rx CH] and SUB STATUS are matched. The data will be echoed when
[Parameter change ECHO] is on. the corresponding metering data will be sent
via [Rx CH] in constant interval for a given period of time (The interval and
time will vary depending on devices).
When Address UL = 0x7F is received, all metering data transmission will be
immediately stopped [disabled].
Transmission
When [Parameter change ECHO] is on, the message will be sent as it is.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
Digital mixer
GROUP ID
00111110 3E
M7CL
MODEL ID
00010001 11
REMOTE LEVEL METER
DATA
00100001 21
CATEGORY
ADDRESS UL
DATA
0mmmmmmm mm
ADDRESS LU
0mmmmmmm mm
ADDRESS LL
0mmmmmmm mm
Count H
0ccccccc ch
Count L
0ccccccc cl
End of exclusive
EOX
11110111 F7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

M7cl-48M7cl-48es

Inhaltsverzeichnis