Technical Data

EU low-voltage directives
73/23/EEC and RL93/68/EEC
EU directive EMC 89/336/EEC
EU machine directive
89/392/EEC
Approval
Switching at the input
Type of cooling
Permissible ambient and cooling-
medium temperature
during operation
during storage
during transport
Installation altitude
Permissible humidity rating
Climatic class
Degree of pollution
Overvoltage category
Degree of protection
Class of protection
Shock protection
Radio interference suppression
Standard
Options
Interference immunity
Paint finish
Mechanical specifications
- Vibrations
During stationary use:
Constant amplitude
of deflection
of acceleration
During transport:
of deflection
of acceleration
- Shocks
- Drop and topple
Siemens AG
6SE7087-6NP85-0AA0
SIMOVERT MASTERDRIVES
EN 50178
EN 61800-3
EN 60204-1
UL:
E 145 153
CSA: LR 21 927
2 switching operations per minute
Air cooling with built-in fan or
air-cooling with additional water cooling
0° C to +40° C ( 32° F to 104° F)
(up to 50° C see Fig. "Derating curves")
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
≤ 1000 m above sea level (100 % load capability)
> 1000 m to 4000 m above sea level
(for load capability. see Fig. "Derating curves")
Relative humidity
Class 3K3 to DIN IEC 721-3-3 (during operation)
Pollution degree 2 to IEC 664-1 (DIN VDE 0110. Part 1).
Moisture condensation during operation is not permissible
Category III to IEC 664-1 (DIN VDE 0110. Part 2)
IP20 EN 60529
Class 1 to EN 536 (DIN VDE 0106. Part 1)
to EN 60204-1 and DIN VDE 0106 Part 100 (BGV A2)
to EN 61800-3
No radio interference suppression
Radio interference suppression filter for Class B1 or A1 to EN 55011
Industrial to EN 61800-3
For interior installation
to DIN IEC 68-2-6
0.075 mm in the frequency range 10 Hz to 58 Hz
9.8 m/s² in the frequency range > 58 Hz to 500 Hz
3.5 mm in the frequency range 5 Hz to 9 Hz
9.8 m/s² in the frequency range > 9 Hz to 500 Hz
to DIN IEC 68-2-27 / 08.89
30 g. 16 ms half-sine shock
to DIN IEC 68-2-31 / 04.84
on a surface and on a corner
Table 9-1
General data
Operating Instructions
≤ 95 %
during transport and storage
≤ 85 %
during operation (moisture
condensation not permissible)