Defecţiune
Saw blade gets loose after
turning off the motor
Motor does not start
No motor output turns off
automatically
Burns on the cutting surface

Remedierea avariilor

Cauza posibilă
Remediere
Fastening
Tighten fastening nut, M20 lefthanded thread
nut tightened
insufficiently
a) Fastening
a) Check the mains fuse.
nut tightened
insufficiently
b) Extension cable
b) See „Electrical Connection" in the operating manual
defect
c) Connections on
c) Have it checked by an electrician
the motor or switch
defect
Overload by
Insert a sharpened saw blade; motor can be turned on again
dull saw blade,
after the cooling period
thermoprotection is
triggered
c) with longitudinal
c) Exchange the longitudinal stop
cuts
d) with cross cuts
d) Align the slide carriage with the saw blade
a) Fastening
a) Tighten fastening nut, M20 lefthanded thread
nut tightened
insufficiently
b) Wrong saw blade
b) Insert saw blade with 20 or 28 teeth for longitudinal cuts
189