Diaphragm Pumps PJ19424-726 EX
Translation of Original Operating- and Installation Instructions, english, KNF PJ19424-726 EX 09/16
2.4.5. Types of protection
Marking
Description
b
Control of ignition sources
c
Constructional safety
d
Flame-proof enclosure
fr
Flow restricting enclosure
k
Liquid immersion
p
Pressurization
Tab. 6
2.4.6. Additional conditions
Marking
Description
-
Equipment can be used without restrictions
X
Special additional conditions
U
Ex component with partial certification, cannot
be used alone; CE conformity is certified when
installed in a complete system.
Tab. 7
Additional conditions for diaphragm pump PJ19424-N726 Ex:
The pump must not be installed outdoors (outside). Putting into
service only with a suitable weather and corrosion protection
covering (hood).
Use