Herunterladen Inhalt Inhalt Diese Seite drucken

M&C MP47-Z Ex Betriebsanleitung Seite 37

Vorschau ausblenden Andere Handbücher für MP47-Z Ex:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Diaphragm Pumps PJ19424-726 EX
T1
I
Methane
IIA
Acetone
Ethane
Ethyl acetate
Ammonia
Ethyl chloride
Benzole
Acetic acid
Carbon monoxide
Methane
Methanol
Methyl chloride
Naphthalene
Phenol
Propane
Toluene
IIB
City gas
IIC
Hydrogen
Transferred medium
Pump environment
Translation of Original Operating- and Installation Instructions, english, KNF PJ19424-726 EX 09/16
2.4.4. Explosion groups
Flammable gases and vapors are classified according to explosion
groups (I, IIA, IIB and IIC) and temperature classes. Tab. 5 shows
the classification of the most common flammable gases and va-
pors.
T2
T3
i-Amyl acetate
Gasoline
n-Butane
Diesel fuel
n-Butyl alcohol
Jet fuel
Cyclohexanon
Heating oil
1.2-Dichloroethane
n-Hexane
Acetic acid-
anhydride
Ethylene
Hydrogen
Ethyl alcohol
sulfide
Acetylene
Tab. 5
The classification of gases and vapors in groups with regard to
their explosion group and temperature class applies both to the
medium transferred and to the pump environment.
The pump may only be used to transfer gases and vapors which
belong to the explosion groups II A and II B and the temperature
class T4 (and below) (marked range in Tab. 5) or which are not
explosive.
The pump may only be operated in an environment which contains
an atmosphere belongs to the explosion groups II A and II B and
the temperature class T4 (or below) (marked range in Tab. 5) or
which is not explosive.
.
T4
T5
Acetaldehyde
Ethyl ether
Use
T6
Carbon
disulfide
7

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Mp serieMp47 ex02p1200

Inhaltsverzeichnis