Set CDT, information includes (Fig. 91):
> Graphics CDT and SEt.
> Timer setting (min:sec), with the Minutes digits flashing.
• S (hold) - to scroll upward through Minute values (8/sec) from 0: to 59: in increments of 1: (min).
• A (< 2 sec) - to step upward through Minute values one at a time.
• M (< 2 sec) - to step back (down) through Minute values one at a time.
• A (< 2 sec) - to save the Minute setting and flash the Second digits.
• S (hold) - to scroll upward through Second values (8/sec) from :00 to :59 in increments of :01 (sec).
• S (< 2 sec) - to step upward through Second values one at a time.
• M (< 2 sec) - to step back (down) through Second values one at a time.
• A (< 2 sec) - to save the min:sec setting and revert to the CDT Status screen with the graphic OFF flashing.
• M (2 sec) - to revert to the FREE Surface Main screen
• Revert to the FREE Surface Main screen after 2 minutes if no button is pressed.
• L (press) - to activate the Backlight.
FREE DIVE EDT (ELAPSED DIVE TIME) ALARM
The EDT Alarm is factory set for 30 seconds. When set ON, the Alarm will sound 3 short beeps and the graphic EDT and Time
digits will flash every time 30 seconds elapse during dives.
• A + S (2 sec), while viewing the FREE Surface Main - to access Set Free EDT Alarm.
> The EDT Alarm can only be Set while on the Surface and cannot be changed during a Dive.
Set EDT Alarm, information includes (Fig. 92):
> Graphics EDT, 30 with clock icon, and SEC.
> Graphic OFF (or ON) flashing.
• S or M (< 2 sec) - to toggle between ON and OFF.
• A (< 2 sec) - to save the setting and access Set DA 1.
• A (2 sec) - to step back to the FREE Surface Main, without changing the setting.
• A & S (2 sec) - to revert to the Surface Main.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
FREE DIVE DEPTH ALARMS (DA)
Free Dive mode features 3 Depth Alarms (DAs) that can be set at progressively deeper Depths and turned OFF/ON.
> If Alarm 1 is set OFF, then Alarms 2 and 3 will be disabled.
> If Alarm 2 is set OFF, Alarm 3 will be disabled.
When each alarm Depth set is reached during a dive, 3 short beeps will sound 3 times and the graphic DA1 (DA2, DA3) and
the Depth digits will flash.
• A (< 2 sec), while viewing the Set EDT Alarm screen - to access Set DA1.
Set DA1, information includes (Fig. 93):
> Graphic DA1.
> Graphic OFF (or ON) flashing.
> Depth digits, flashing when ON is selected, with MAX and FT (or M) icons.
• S or M (< 2 sec) - to toggle between OFF and ON.
• A (< 2 sec) - to save the ON/OFF setting.
>
If OFF is selected, operation reverts to the Surface Main.
>
If ON is selected, the Depth digits will flash allowing them to be set.
• S (press/hold), if ON - to scroll upward through the Depth values 8/sec from 30 to 330 FT (10 to 100 M) in increments of
10 FT (1 M).
• S (< 2 sec) - to step upward through the Depth values one at a time.
• M (< 2 sec) - to step back (down) through the Depth values one at a time.
• A (< 2 sec) - to save the setting and access Set DA2 (or DA3); or after setting DA3 revert to Free Surface Main.
• A (2 sec) - to step back to the Set EDT Alarm screen, without changing the setting.
• A & S (2 sec) - to revert to the Surface Main.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
Set DA2 and DA3 are similar.