HIGH O2
The %O2 represents oxygen accumulated as a result of the repetitive Nitrox dives you have conducted during that operating
period. The %O2 displayed on the ALT screen lets you monitor how close you are coming to the limits of oxygen exposure.
If the theoretical amount of oxygen accumulated reaches 80% of the limit for a single exposure, or 24 hour period (240 OTU =
80%), the Audible will sound during which the O2 % vlaue flashes in place of NDC time if in No Deco, or TAT if in Deco (Fig.
73).
If O2 reaches 100% of the exposure limit (300 OTU), the Audible will sound again, 100 % O2 will replace NDC or TAT (Fig.
74), and the Up Arrow icon will flash until on the surface.
• S (< 2 sec) - to acknowledge/silence the Audible.
• A (< 2 sec) - to view ALT screens.
• M (2 sec) - to access the Gas Switch Routine.
• L (press) - to activate the Backlight.
Upon surfacing, operation will lock into NORM mode until the O2 decreases below 100%. Access to Watch Mode is allowed
but access to GAUG and FREE is blocked.
•...Plan.each.dive,.and.dive.your.plan...the.talis.was.not.designed.to.make.decisions.for.you,.only.to.provide.you.with.the.information.
you.need.to.make.responsible.decisions.for.yourself...this.begins.with.a.dive.Plan.that.will.help.you.avoid.a.low.air.or.decompression.
situation.
•...Do.not.plan.any.dive.that.exceeds.your.training.or.experience.level.
•...Inspect.your.talis.before.every.dive...If.it.shows.any.signs.of.damage.or.abnormal.function,.Do.not.dive.with.it.until.it.has.received.
factory.prescribed.service.
•...Make.a.safety.stop.at.15.to.20.Ft.(4.5.to.6.M).at.the.end.of.every.dive...It's.important,.don't.forget.it..
•...You.should.make.every.effort.to.complete.all.of.your.ascents.with.the.nitrogen.Bar.Graph.inside.the.normal.no.Decompression.zone.
•...If.you.inadvertently.entered.Decompression,.you.should.not.complete.your.ascent.until.the.nitrogen.Bar.Graph.is.at.least.inside.the.
no.Decompression.Caution.Zone.
•...While.you.cannot.provide.a.guarantee.against.the.occurrence.of.decompression.sickness,.you.may.choose.your.own.personal.zone.
of.caution.based.upon.your.individual.age,.physique,.excessive.weight,.training,.experience,.etc..to.reduce.the.statistical.risk...By.not.
pushing.the.limits,.you.can.establish.and.adjust.your.personal.level.of.conservatism.and.margin.of.safety.
©2002 Design, 2014
--------------------------------------------------------------------------------------------------------
RESPONSIBLE COMPUTER DIVING
31
TALIS
OWNER'S MANUAL
Fig. 73 - O2 WARNING
(No Deco, during Audible)
Fig. 74 - O2 ALARM
(Deco, until on surface)
Doc. No. 12-5355-r01 (1/20/14)