SET GAS 2 is similar to Set Gas 1.
SET FO2 50% DEFAULT, information includes (Fig. 29):
> Graphics FO2, dFLt, and 50.
> Graphic OFF (or ON), flashing.
• S or M (< 2 sec) - to toggle between OFF and ON.
• A (< 2 sec) - to save the setting and revert to the Set Gas screen.
• A (2 sec) - to step back to the Set Gas 2 screen, without changing the setting.
• A & S (2 sec) - to revert to the SET GAS screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET A (ALARMS)
Group selections >> Audible >> Depth >> EDT >> NIBG >> DTR.
> A & S (2 sec), while viewing the Set Gas screen - to access the SET A lead-in screen (Fig. 30).
> A (< 2 sec) will then access Set Audible Alarm.
SET AUDIBLE ALARM, information includes (Fig. 31):
Due to their importance, some cautionary situations will force the Audible to sound even if this feature is set to Off.
> Graphic AUD.
> Graphic ON (or OFF), flashing.
• S or M (< 2 sec) - to toggle between ON and OFF.
• A (< 2 sec) - to save the setting and access Set Depth Alarm.
• A (2 sec) - to step back to the SET A screen, without changing the setting.
• A & S (2 sec) - to revert to the SET A screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET DEPTH ALARM information includes (Fig. 32):
> Graphic DEP.
> Depth digits, flashing, with MAX and FT (or M) icons.
• S (press/hold) - to scroll upward through set points 8/sec from 30 to 330 FT (10 to 100 M) in increments of 10 FT (1 M).
• S (< 2 sec) - to step upward through the set points one at a time.
• M (< 2 sec) - to step back (down) through the set points one at a time.
• A (< 2 sec) - to save the setting and access Set EDT Alarm.
• A (2 sec) - to step back to the Set Audible Alarm screen, without changing the setting.
• A & S (2 sec) - to revert to the SET A screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET EDT ALARM, information includes (Fig. 33):
> Graphic EDT (Elapsed Dive Time).
> Time digits (hr:min), flashing, with wave/clock icon.
• S (press/hold) - to scroll upward through the set points 8/sec from 0:10 to 3:00 (hr:min) in increments of 5 minutes (:05).
• S (< 2 sec) - to step upward through the set points one at a time.
• M (< 2 sec) - to step back (down) through the set points one at a time.
• A (< 2 sec) - to save the setting and access Set NiBG Alarm.
• A (2 sec) - to step back to the Set Depth Alarm screen, without changing the setting.
• A & S (2 sec) - to revert to the SET A screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET NiBG ALARM, information includes (Fig. 34):
> Graphic NBG (Nitrogen Bar Graph).
> NIBG segments, flashing.
• S (< 2 sec) - to step upward through the set points from 1 to 5 segments one at a time.
• M (< 2 sec) - to step back (down) through the set points one at a time.
• A (< 2 sec) - to save the setting and access Set DTR Alarm.
• A (2 sec) - to step back to the Set EDT Alarm screen, without changing the setting.
• A & S (2 sec) - to revert to the SET A screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
©2002 Design, 2014
--------------------------------------------------------------------------------------------------------
18
TALIS
OWNER'S MANUAL
Fig. 29 - SET FO2 50%
DEFAULT
Fig. 30 - SET ALARMS
LEAD-IN
Fig. 31 - SET AUDIBLE
ALARM
Fig. 32 - SET DEPTH ALARM
Fig. 33 - SET EDT ALARM
Fig. 34 - SET NiBG ALARM
Doc. No. 12-5355-r01 (1/20/14)