SET DTR ALARM, information includes (Fig. 35):
> Time digits (hr:min), flashing, with wave/clock/profile and AIR icons.
• S (press/hold) - to scroll upward through the set points 8/sec from 0:00 to 0:20 (min) in increments of 1 minute (0:01).
• S (< 2 sec) - to step upward through the set points one at a time.
• M (< 2 sec) - to step back (down) through the set points one at a time.
• A (< 2 sec) - to save the setting and access Set Turn Alarm.
• A (2 sec) - to step back to the Set NiBG Alarm screen, without changing the setting.
• A & S (2 sec) - to revert to the SET A screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET U (UTILITIES)
Group selections >> Wet Activation >> Units >> Deep Stop >> Safety Stop >> Conservative Factor >> Backlight Duration >>
Sampling Rate.
> A & S (2 sec), while viewing the SET A screen - to access the SET U lead-in screen (Fig. 36).
> A (< 2 sec) will then access Set Wet Activation.
SET WET ACTIVATION, information includes (Fig. 37):
> Graphics WET and ACt.
> Graphic OFF (or ON) flashing.
• S or M (< 2 sec) - to toggle between ON and OFF.
• A (< 2 sec) - to save the setting and access Set Units
• A (2 sec) - to step back to the SET U screen, without changing the setting.
• A & S (2 sec) - to revert to the SET U screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET UNITS, information includes (Fig. 38):
> Icons/graphics PSI, F, and FT (or BAR, C, and M), flashing.
• S or M (< 2 sec) - to toggle between Imperial and Metric.
• A (< 2 sec) - to save the setting and access Set Deep Stop
• A (2 sec) - to step back to the Set Wet screen, without changing the setting.
• A & S (2 sec) - to revert to the SET U screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
SET NORM DEEP STOP, information includes (Fig. 39):
> Graphic DS (Deep Stop).
> Graphic OFF (or ON), flashing, with STOP icon.
• S or M (< 2 sec) - to toggle between OFF and ON.
• A (< 2 sec) - to save the setting and access Set Safety Stop.
• A (2 sec) - to step back to the Set Units screen, without changing the setting.
• A & S (2 sec) - to revert to the SET U screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
The DS is factory set for 1/2 Max Depth for 2 minutes.
SET NORM SAFETY STOP, information includes (Fig. 40):
> Graphic SAF (Safety Stop).
> Graphic OFF (or ON), flashing, with STOP icon.
• S or M (< 2 sec) - to toggle between OFF and ON.
• A (< 2 sec) - to save the setting and access Set Conservative Factor.
• A (2 sec) - to step back to the Set Deep Stop screen, without changing the setting.
• A & S (2 sec) - to revert to the SET U screen.
• M (2 sec) - to revert to the Surface Main.
• Revert to the Surface Main after 2 minutes, if no button is pressed.
The SS is factory set for 15 FT (5 M) for 3 minutes.
©2002 Design, 2014
--------------------------------------------------------------------------------------------------------
.
.
19
TALIS
OWNER'S MANUAL
Fig. 35 - SET DTR ALARM
Fig. 36 - SET U (UTILITIES)
Fig. 37 - SET WET
ACTIVATION
Fig. 38 - SET UNITS
Fig. 39 - SET DEEP STOP
Fig. 40 - SET SAFETY STOP
Doc. No. 12-5355-r01 (1/20/14)