Herunterladen Inhalt Inhalt Diese Seite drucken

Programming Magicsafe - Waeco MagicSafe MS-670 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
_MS-670.book Seite 45 Donnerstag, 8. Mai 2008 4:55 16
MagicSafe MS670
Connecting the ultrasonic senors
➤ Insert the red plug of the ultrasonic sensor cable (12) in the red
connection of the ultrasonic sensor (12).
➤ Insert the white plug of the ultrasonic sensor cable (13) in the white
connection of the ultrasonic sensor (13).
Connecting the indicator / Yellow/red (P15)
This is cable is used to influence the output signal of both indicator outputs.
If the indicators are postively charged (the cables to the indicators conduct
+12 V, when the indicators are activated):
➤ Connect this cable to a cable with a permanent +12 V charge which is
protected by a 10 A fuse.
If the indicators are negatively charged (the cables to the indicators conduct
an earthed charged, when the indicators are activated):
➤ Connect this cable to earth (terminal 31).
Yellow (P14 and P16)
➤ Connect one yellow cable (P14) to the right indicator cable.
➤ Connect the other yellow cable (P14) to the left indicator cable.
8

Programming MagicSafe

8.1
Programming the vehicle code
The alarm system must be adjusted to the CAN bus of your vehicle type. To
do this, you must enter a vehicle code after the installation and the electrical
connection of the alarm system. If necessary, contact your vehicle
manufacturer.
To program the vehicle code, proceed as follows:
➤ Press the button (fig. 5 4, page 5) on the control unit and hold it down.
➤ When the LED on the control device (fig. 5 3, page 5) lights up, release
the button.
✓ The LED goes out.
Programming MagicSafe
45

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis