Herunterladen Inhalt Inhalt Diese Seite drucken

Digital Output: Aes-Ebu; Reposition The Ground Lift Switch (Optional) - AKG DMS800 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für DMS800:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

commissioning
AES‑EBU
GROUND LIFT
DMS800 MANUAL
CAUTION: If you set the IP address of the Dante™ network manually via the
software, it is essential that you note down the IP address set.
Alternatively, before removing the device from the network, set the IP ad‑
dress to "Automatic" using the software so that the device is detected in a
new network by the Dante™ Controller Software.
To connect the Dante™ digital output, proceed as follows:
Step
Description
1
Connect the Dante™ digital output according to the Dante™
Controller Software with the required Dante™ digital input
6.4.3
Digital output: AES‑EBU
To connect the digital outputs, proceed as follows:
Step
Description
1
Connect the balanced AES‑EBU digital output on the XLR
socket (25) to the required AES‑EBU digital input
The integrated Wordclock Generator supports a sampling rate of 48 kHz.
To synchronise all digital signals on the system, an external 48 kHz clock
generator can be connected to the BNC socket Wordclock IN (24).
The receiver detects the external 48kHz clock signal automatically and uses
the external clock signal from this time. The current clock status can be
checked in the channel window.
6.5

Reposition the GROUND LIFT switch (optional)

The GROUND LIFT switch (16, 19) is used to isolate the housing mass con‑
nection: This allows hum caused by earth loops to be removed.
To isolate the housing mass connection, proceed as follows:
Step
Description
1
Move the GROUND LIFT switch (16, 19) in the LIFT position
The switch position is displayed in the channel window.
80

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis