10. Option overview

Available Options
A
6- / 5-digit coin counter
B1
No coin acceptence during power outage
Acoustic signal before time laps can be set by
C1
factory
C2
With potential-free contact for e.g. external alarms
D
E
Key-switch for moneyless release
F
Time stopp automatic at 100 mA
3-phase contactor 3 x 20 A (recommended from
G
2,2 kW)
L
24 V safety low voltage for humid areas
M
Push-button for door release
O
Multiple coin tester**; release amount adjustable
Q1
Lead time adjustable
Q2
Relay for follow-up time, time adjustable
S
External start
T
Burglary protection with additional steel-bar
U
Same lock as housing
V
6-digit operating hour counter
Electonical time control for showers with included
Z
1/2 inch magnetic valve and 230 V/24 V transformer
Coin insertion EURO coins
0,10 Euro
0,20 Euro
0,50 Euro
1,00 Euro
2,00 Euro
Coin insertion Token
Standard token Ø 26 mm
Ø 25 mm
Please order tokens separately.
Order note
In case of order note type and letter for recommended optional
features:
e.g.
ZMZ 0205, 1,00€, A, T, Z
Item No.
70530172, 3000, 3200, 3280
NZR – Ihr Partner für Energiemessung
Item no.
ZMZ 0205
3000
5-digit
3010
-
3020
-
3021
-
3030
-
3040
3050
-
3061
3120
3130
-
3151
-
3240
-
3250
-
3180
-
3200
3210
3190
-
3280
Additonal item no.
*
_ _ _ _ _ _ 69
_ _ _ _ _ _ 70
1
_ _ _ _ _ _ 71
_ _ _ _ _ _ 72
2
_ _ _ _ _ _ 73
3
4
Additonal item no.
Note
_ _ _ _ _ _ 74
_ _ _ _ _ _ 76
ZMZ 0215
ZMZ 0215
LMZ 0115*
Wash'n Dry
3
6-digit
Standard
4
4
3
1
-
Standard
-
2
Standard
-
valid for billing - calibrated design
Available special features (In case of misorders the withdrawal of
devices is excluded.)
Not in combination with option „L", „G" or „M"
option „G" (control contactor).
With option „O" as default.
C1 and C2 only available separately, can not be combined.
Option „G" not available in combination with option „L".
Time control for showers with magnetic valve
• Option „Z" is required if a 230 V connection is available at
installation place.
• Option „L" and a magnetic valve 1/2" (Item no. 5170) is required
if a 24 V connection is available at installation place.
required if one device should handle up to 5 showers with
magnetic valve.
Just contact us with any question!
LMZ
LMZ 0232*
0236*/0436*
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Item no.
13201
-
-
-
19

Quicklinks ausblenden: