2. Before mounting

2. Before mounting
2.1 Transmitters with standard measuring ranges
Series T19 transmitters with standard measuring ranges are configurable
by means of solder bridges. Access to the solder bridges is gained after
removing the bottom of the casing. Mounted transmitters have to be
dismantled first before they can be configured.
To work properly, the transmitter has to be configured. Make
sure that the transmitter is configured before mounting.
Configuration is to be carried out as described in section 3.
As an option standard measuring ranges can be configured at the factory
and in this case the appropriate measuring range is printed on the rating
plate. Transmitters with standard measuring range configured at the
factory can be immediately fitted at the measuring point and put into
operation.
2.2 Transmitters with special measuring ranges
Series T19 transmitters with special measuring ranges cannot be
reconfigured. Special measuring ranges can be recognised by a 9 as last
digit in the model designation: T19.x0-xx0-9
Special measuring ranges are configured at the factory and can be
immediately fitted at the measuring point and put into operation.
WIKA operating instructions temperature transmitter, model T19