Herunterladen Inhalt Inhalt Diese Seite drucken

Ambient Conditions; Measuring Ranges; Measuring With The Benning Sun; Preparing The Measurement - Benning SUN 2 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für SUN 2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

All measuring results are displayed on the large LC display.
-
Storage capacity of the data logger: 5000 data records, including the values for insolation,
module temperature and ambient temperature as well as a time / date stamp
-
integrated real-time clock
-
Interface: USB
-
Dimensions of the device:
(L x W x H) = 150 x 80 x 33 mm
-
Weight of the device:
265 g without temperature sensors / USB cable
347 g including temperature sensors / USB cable
6.

Ambient conditions

-
The BENNING SUN 2 is intended for measurements under dry ambient conditions,
-
Maximum barometric height for measurements: 0 m to max. 2000 m
-
Contamination level: 2
-
Protection category: IP 40 (DIN VDE 0470-1, IEC/ EN 60529)
4 – first index: protection against access to dangerous parts and protection against solid
impurities of a diameter > 1.0 mm
0 – second index: No protection against water
-
EMC: IEC/ EN 61326,
-
Operating temperature and relative air humidity:
For operating temperatures from 0 °C to 50 °C: relative air humidity lower than 80 %, non-
condensing
-
Storage temperature: The BENNING SUN 2 can be stored at temperatures between - 20 °C
and + 60 °C (air humidity 0 to 80 %). During storage, the batteries must be removed.
7.

Measuring ranges

Note: The measuring accuracy is specified as the sum of:
-
a relative part of the measured value and
-
a number of digits (i.e. counting steps of the last digit).
This measuring accuracy applies to temperatures from 0 °C to 50 °C and a relative air humidity
lower than 80 %.
7.1 Insolation
Measuring range
100 Wm² to 1250 Wm²
30 BTU/h/ft² to 400 BTU/h/ft²
7.2 Module temperature and ambient temperature
Measuring range
- 30 °C to + 125 °C
- 22 °F to + 257 °F
7.3 Angle of inclination
Measuring range
0° to 80°
7.4 Compass bearing (orientation)
Measuring range
0° to 360°
8.

Measuring with the BENNING SUN 2

8.1 Preparing the measurement

Operate and store the BENNING SUN 2 at the specified storage and operating temperatures
only!
-
Strong sources of interference in the vicinity of the BENNING SUN 2 might involve unstable
readings and measuring errors.
Before commissioning, always check the device as well as all connecting
cables for damages.
03/ 2012
Resolution
1 W/m²
1 BTU/h/ft²
Resolution
1 °C
1 °F
Resolution
Resolution
BENNING SUN 2
Measuring accuracy
± (5 % + 5 digits)
± (5 % + 5 digits)
Measuring accuracy
± (1 % + 1 digit)
± (1 % + 1 digit)
Measuring accuracy
± 2°
Measuring accuracy
± 10°
10

Werbung

Kapitel

Inhaltsverzeichnis
loading