12 Other notes on operation
If the device reaches too high a temperature during
operation (due to insufficient air circulation, for exam-
ple), the load will first of all be reduced by lowering the
brightness. If the overtemperature persists, the load
will be disconnected.
If the actuator is operating via the HomeMatic central
control unit (CCU), please note that the central control
unit will not be informed in the event of a load failure.
13 Technical specifications
Device designation:
Supply voltage:
Minimum load:
Maximum switching
capacity:
Current consumption:
Power consumption in
standby:
Dimming method:
Kind of load:
Radio frequency:
Receiver class:
HM-LC-Dim1T-Pl-3
230 V/50 Hz
10 VA
300 VA
1.3 A (max.)
1 W
Reverse phase control
ohmic and capacitive
lamp load
868.3 MHz
SRD Class 2