Warning displays (error codes) for incorrect

settings in flash mode
The camera's manual operating concept and the
many options, particularly with system flash
Error
code:
Cause:
Camera in the metering flash mode ( F )
and flash unit in TTL control
Camera in the metering flash mode ( F )
and flash unit in computer automatic
Camera in strobe flash mode with camera modes
P or T
Camera in the metering flash mode (F)
and shutter speed setting ring at X,
flash unit in
The film speed is below ISO 25/15°.
The film speed is above ISO 400/27°.
units, allow settings that do not make sense. In
such cases, an error message e.g.
appears in the viewfinder.
Remedy:
Flash unit must be set to manual
Flash unit must be set to manual
Set camera to m or A
Set the shutter speed setting ring to any time
except for X or B.
The metering flash function is only possible for film
speeds between ISO 25/15° and ISO 400/27°, so
another film speed must be used.