Indicator lamp pump
1x blinking
Lack of oil
 Replenish oil.
2x blinking
Leak in the high pressure system
 Check high pressure system and con-
nections for tightness.
3x blinking
Lack of water after 2 minutes - the pump
is switched off to prevent dry runs.
 Check water supply, check connec-
tions.
4x blinking
Heater contactor fault
 Set the appliance switch to "0/OFF".
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service
"Low water" indicator lamp
Lack of water - heater is switched off
 Check water supply, check connec-
tions.
Indicator lamp "Ready for use"
No line voltage, see "Appliance is not
running".
Indicator lamp for heater lights up
Heater operation
Engine indicator lamp
2x blinking
Engine overload/overheat
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service
26
turns off
3x blinking
Fault in the voltage supply.
 Check main connections and mains
fuse.
4x blinking
Excessive power consumption.
 Check main connections and mains
fuse.
 Inform Customer Service
Indicator lamp boiler fault
1x blinking
Temperature limiter has got triggered.
 Set the appliance switch to "0/OFF".
 Allow device to cool down.
 Turn on the appliance.
Error occurs repeatedly.
 Inform Customer Service
3x blinking
System care detection defective
 Inform Customer Service
4x blinking
Temperature sensor defective
 Inform Customer Service
Indicator lamp service
Service interval
 Perform service work.
Indicator lamp system care is
Note: Heater can only operate 5 more
hours.
System care bottle empty.
 Replace the system care bottle.
Indicator lamp system care is
Note: Heater operation no longer possible.
System care bottle empty.
 Replace the system care bottle.
Appliance is not running
No power
 Check power connection/conduit.
– 9