Assembly in the ball valve

Close the ball valve.
Unscrew the sealing plug from the ball valve.
Place an O-ring from the enclosed set on the assembly
pin (1). The second O-ring is a spare part.
Screw the O-ring with the assembly pin into the ball
valve's sealing plug bore hole (2).
Place the O-ring in its fi nal position using the other end
of the assembly pin (3).
Put the assembly pin over the temperature sensor with
the sleeve end – as far as it will go (4).
Clasp the temperature sensor with both halves of the
plastic screw directly over the assembly pin. Press both
halves together so that both pins from one half fi t in the
bore holes in the other half.
Remove the assembly pin from the temperature sensor (5).
Insert the temperature sensor with the plastic screw in the
ball valve and tighten the plastic screw hand-tight (6).
Check the leak tightness.
M-bus module connection
Remove the user locking device from the calculator casing
and open the lid.
Slot 1 is intended for the M-bus module:
The M-bus module is a serial interface with the following
properties:
– M-bus module standardised according EN 1434-3
– Capability of connecting 2 x 2.5 mm²
– Galvanic isolation
– Maximum voltage: 50V DC,
– Current consumption: one M-bus load
– Primary or secondary addressing
– Baud rate 300 or 2400 bauds.
A 2-pole connector block is at-
tached to the circuit board with
the marked connections 24 and
25. They must be connected to
the M-bus master.
Push the plugs onto the cir-
cuit board carefully (see fi g.
on the right-hand side).
Insert the circuit board into
the upper locking point and
position it between it and the
lower installation point as far as it will go. Screw it down
tight with 2 cross slot screws:
Close the lid.
Check the function by pressing the push button.
Seal the calculator.
Connecting the pulse output module
Slot 2 is intended for the pulse output module
Properties of the pulse output module:
– External power supply V
– Output current ≤ 20 mA with a residual voltage ≤ 0.5 V
– Open collector (drain)
– Pulse values 100-150 ms
– Potential-free contact
– Energy pulse valence according to the display unit (last
digit in the display),
– Volume pulse valence = last digit of the on-screen volume
display (standard: 1L/pulse).
A 4-pole connector block is attached
to the circuit board with the mar-
ked connections („A" for energy
pulse output and „B" for volume
output).
Push the plugs onto the circuit
board carefully (see fi g. on the
right-hand side).
= 3-30 V DC
ex