9.

Maintenance and repair

WARNING! Before carrying out any repair or maintenance work observe safety warnings and
always disconnect mains plug
We recommend our authorised NOVOPRESS workshops for maintenance and repair work (see Service
addresses).
The tool must be serviced by a qualified technician only.
The next recommended date for servicing is shown on press jaws, intermediate jaws, press collars and
press tools.
Regularly:
Check mains connection lead, including plug and extension cable, for signs of external damage and have
them repaired if necessary.
Clean and lubricate press tool (see Section 8 Cleaning and lubrication).
Every 6 months:
Press tool
Inspection to DIN VDE 0701-1 and DIN VDE 0702 for Class I electric power tools by a qualified electrician,
an authorised workshop or Novopress Neuss
Press jaws/intermediate jaws
Check screw joints and tighten if necessary.
Check jaw levers for ease of action.
Press collars
Check moving segments (C), catch (V) and curved sections (D) for ease of action.
Once a year:
Have press jaws, intermediate jaws, press collars and press tools checked by an authorised NOVOPRESS
workshop.
(Also see warranty conditions for new equipment)
Use GENUINE NOVOPRESS REPLACEMENT PARTS ONLY.
10. Brief description of LED indicator
x = LED is on (steady)
b = LED flashing
- = LED is off
To rectify the following faults, always:
1. press Stop button (2),
2. press Start button (1) until piston is fully retracted.
green
red
Cause
LED
LED
-
-
• Mains cable not connected.
• Mains cable faulty.
b
-
• Retaining pin incorrectly inserted
• Intermediate jaw incorrectly
positioned against a press collar.
• Closed jaw sensor faulty or press
jaw is closed.
• Contacts (15), (16) or (30) dirty
• Press jaws not compatible with
x
b
control system
Fault signals before press tool could start:
Remedy
• Connect mains plug to a power supply.
• Get a qualified electrician to change the faulty
mains cable for a new mains cable
• Push in retaining pin all the way.
• Re-position intermediate jaw.
• Open press jaw. If the green light continues to
flash the closed jaw sensor is faulty.Closed jaw
sensor is faulty if yellow lamp continues to show
• Clean contacts.
• Only use press jaws provided.
13