Protection against electric shock
: Internally powered equipment/Class II equipment, Type BF
applied part
Mode of operation
: Continuous operation
Classification
: Internally powered equipment/Class II
Key to symbols
: Type BF applied part
: Class II equipment
: Refer to instruction manual/booklet.
: The used electrical and electronic products are not household
waste. Follow your national/local recycling rules to dispose of
P R E C A U T I O N S A N D C O N T R A I N D I C A T I O N S
Do not use this product without consultation with your doctor if you are under
dialysis therapy or on anticoagulants, antiplatelets or steroids. Use of this
instrument under such conditions could cause internal bleeding.
For specific information on your blood pressure, contact your physician. Never
make any judgment on your own regarding measurement results.
Do not use this product along with implantable and wearable medical electrical
equipment such as pacemaker, defibrillator, or electrocardiographic monitor.
This product is not also intended to be used with HF surgical equipment.
Do not use this product in an explosive environment such as near flammable
anesthetics or inside oxygen chamber.
The system may fail to yield specified measurement accuracy if operated or
stored in temperature or humidity conditions outside the limits stated in the
specifications section of this manual.
Do not use cuffs or accessories other than those specified by the
manufacturer. Otherwise, correct measurement readings cannot be obtained.
Use of this product in areas near mobile phones, microwave ovens or other
them properly. In the EU countries, please refer to waste
management symbol(s) marked on the package or the
instrument.
This device complies with EN1060-1:1995+A2:2009 Non-invasive sphygmomanometers
Part 1: General requirements, EN1060-3:1997+A2:2009 Non-invasive shygmomanometers
Part 3: Supplementary requirements for electro-mechanical blood pressure measuring
system and EMC (IEC60601-1-2:2007).
*Accuracy is guaranteed with the measured values that are within the measuring range.
Specifications are subject to change without notice due to improvements in performance.
devices with strong electromagnetic field may cause malfunctions.
Do not apply the cuff over wounded arm, arm under an intravascular access or
therapy or an arterio-venous shunt, or arm on the side of a mastectomy.
Otherwise injury may be resulted.
Make sure that inflation of the cuff is not causing prolonged impairment of
blood circulation. Also, be cautious about temporary loss of the functions of
any other medical equipment if any monitoring equipment is used on the same
limb with the blood pressure measuring cuff.
To avoid harmful injury due to interfered blood flow from cuff inflation,
- Make sure that AIR HOSE is not kinking before measurement. Otherwise,
cuff inflation may not be conducted properly and prolonged, and
- Do not make measurements repeatedly.
To avoid any possibility of accidental strangulation, keep this product away
from children and do not drape AIR HOSE around your neck.
Because the product includes precision parts, avoid extreme temperature
variations, humidity, shock, dust, and direct sunlight. Do not drop or strike the