Herunterladen Inhalt Inhalt Diese Seite drucken

Water Connection; Preliminary Check; Hot Water - Sanremo MILANO SAP Bedienungsanleitung

Inhaltsverzeichnis

Werbung

ENGLISH
1) Only cold water must be supplied to the appliances.
2) If the mains water pressure exceeds 6 bar, a pressure reducer must be installed to regulate the outlet
pressure to a maximum of 6 bar.
3) Connect the drain hose to the tray, avoiding sharp bends and keeping a sufficient slope for regular
flow of the drain water.
4) Connect the 3/8" hose to the mains outlet and then to the water softener and to the appliance.
N.B. A water softener is indispensable for correct appliance operation, best coffee in the cup and long
life of the components, since it removes scale and residues from the water that would otherwise shorten
their life.
The company is relieved of all and any liability in the event of failure to comply with the
above instructions.
Before using the appliance make sure that:
- The power supply is connected correctly.
- The fill hose is correctly connected to the mains water supply, there are no leaks and the water is turned
on.
- The drain hose is positioned according to the instructions and fixed with a hose clip.
With the steam tap (B) open, turn the main switch (D) to position 1 and wait for the water inside the boiler
to reach the maximum level set by the electronic control unit. If the boiler does not fill by the time set
(90 seconds), the pump stops and the LEDs on the keypad start to flash. If this happens, turn the main
switch (D) to the 0 position, then back to 1 to finish filling the boiler.
Turn the main switch (D) to position 2. This activates the electric elements which start heating the water.
Wait for steam to be given off from the steam nozzle (B), then close the tap and check that the pressure
on the Boiler pressure gauge has reached and stays at a value of 0.8:1 bars. If this is not the case, use
a screwdriver to adjust the internal pressure gauge regulation screw (+ to increase, - to decrease, see
figure below).
Ensure that the boiler pressure gauge indicates a pressure of 0.5:1 bar. Turn the tap knob (C) counter-
clockwise.
Pay the utmost attention in order to prevent scald burns.
Except for the 1-group machine that has just one steam nozzle, all the other models have 2 located
at the sides. These steam nozzles are recessed but can swivel out thanks to an articulated joint. To
dispense steam, just turn the knobs (B) counter-clockwise.
Pay the utmost attention in order to prevent scald burns.

Water connection

USE

Preliminary check

Hot water

Steam
27