Herunterladen Inhalt Inhalt Diese Seite drucken

A) Heat Regulation - Solamagic S1 Montage- Und Gebrauchsanleitung

Led-lichtmodulset
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

a) Heat regulation:

Switching on/off:
Short-term heating:
Heating level:
Memory function:
Timed switch off:
Synchronisation:
08/2016
Brief pressing of the programmed wireless channel button
on the hand-held transmitter switches the connected radi-
ant heater on or off.
Double-clicking the programmed wireless channel key
switches the radiant heater on for 15 minutes and then
automatically switches it off again.
Extended pressing of the programmed key on the hand-
held transmitter switches the heat output up and down
between three levels (33, 66 and 100%).
Upon switching back on, a short press of the key recalls
the last heating level.
If a timed switch-off has been activated in the program-
ming, the radiant heater always switches off automatically
after the specified time. The radiant heater signals as fol-
lows after the activating the set residual run time:
Signal duration 2s
-
Signal duration 4s
-
Signal duration 6s
-
If multiple radiant heaters are controlled using the same
hand-held transmitter button, faults in the wireless trans-
mission path can result in different states. For synchroni-
sation, use the function „Heating level" to initially set all
radiant heaters in switched-on state. Then switch off all
receivers by a briefly pressing the key. The „Heating level"
function can now be used to simultaneously set again all
the actuated receivers.