Trouble Shooting

Problem
Machine does not operate
Machine operates with a wobbleor jerky
motion.
Machine circuit breaker trips continuously.

Technical specifications

A.C. motor
Rated power
Max.amp draw
Brush (rpm)
Brush (mm)
Working height (mm)
Working weight
Protection class
Belt- driven
Sound pressure level LPA
Weighted acceleration value
F3/F3+/F8/F12 9002026 (08- 15)
Cause
Faulty power cord.
Tripped circuit breaker
Faulty machine wiring.
Faulty motor.
Capacitor burned out.
Soiled Pad.
Improper pad/brush for application.
Pad driver/brush not installed correctly.
Pad/brush unevenly worn.
Pad not properly centered on pad driver
Heavily soiled pad/brush
Improper pad/brush for application
Defective circuit breaker.
Worn carbon brushes in motor.
F3 low speed
F3+ low speed
230 V: 50 Hz
230 V: 50 Hz
1000 W
5,5 A
165
430
250
31 kg
lPx4
x
59db (A)
1.05 m/sec2
English
Solution
Contact Service Center.
Wait 10 min. till machine cooled down and
try again.
Contact Service Center
Contact Service Center
Contact Service Center
Replace Pad
Change to proper pad/brush
Remove and reinstall pad driver/brush
Replace pad/brush
Remove and reinstall pad driver
Clean or replace pad/brush
Change to proper pad/brush
Contact Service Center
Contact Service Center
F8 high speed
230 V: 50 Hz
1000 W
1100 W
5,5 A
5,5 A
165
400
430
430
250
250
43 kg
31 kg
lPx4
lPx4
x
x
59db (A)
59db (A)
1.05 m/sec2
1.05 m/sec2
EN
F12 Duo speed
230 V: 50 Hz
1200/1500 W
5,2 / 8,1 A
170/340
430
250
37 kg
lPx4
x
65db
1.05 m/sec2