Herunterladen Inhalt Inhalt Diese Seite drucken

Migatronic SIGMA NEXT RC Betriebsanleitung Seite 18

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
How to connect the installation
Main components:
1. Interface
2. Welding inverter
3. Wire feed unit - RWF
2
4. Remote
control
2
Welding process
Distance to work piece
MIG – pulse
MIG – non pulse
Cable dimensions
Welding current
DC
200 A
35 mm²
300 A
50 mm²
400 A
95 mm² / 2x50 mm²
500 A
2x70 mm²
Installing
the Anybus module
1. Important! Once you have installed the Anybus
module, insert the plug straight into the hole.
2. Press the plug slightly into position.
3. Tighten the Anybus module using the screws.
NOTE:
DEFECTIVE CONNECTORS ARE NOT COVERED BY
WARRANTY!!!
18
RWF²
3
d
ROBOT / PLC
c
CONTROLLER
CONTROLLER
Cables and fittings:
a. Signal cable for robot controller
b. CAN communication cable for welding inverter
c.
Interconnection, gas and 2xwelding cable and CAN
d. Welding torch
e. Welding return cable
Total cable length in welding circuit
(
c
+
d
)
10 m
30 m
PULSE
35 mm²
70 mm²
95 mm² / 2x50 mm²
2x70 mm²
3 windings
through core
17440005
SIGMA NEXT RC
Anybus
communication
Anybus interface
a
(
c
+
d
+
e
)
20 m
60 m
1
REMOTE²
4
b
1
2
e
Total length of CAN cable
(
b
+
c
)
30 m
30 m
2
3
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Sigma next rc 400

Inhaltsverzeichnis