Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Techem Basic Series Bedienungsanleitung

Optischer rauchwarnmelder (rwm) zum schutz von privatwohneinheiten in wohngebäuden.
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

  • DEUTSCH, seite 1
Techem smoke detector basic – operating instructions

Technical data

Sensor type
Acoustic alarm
Press the detector head
(entire cover)
Function display
Self-test functions
Installation
Power supply
Battery working life
VdS [German safety organi-
sation] approval according
to EN14604
Optical
Fire alarm: 3 kHz + 0,5 kHz,
> 85 dB(A) at 3 m distance
• For manual alarm testing
• For muting the alarm for 10 minutes
Light signal every 344 s
• Battery low test every 344 s
• Self-test for the measurement
chamber every 43 s
• On ceilings and roof pitches
• 6 m max. room height
• 60 m² max. monitoring area
• Permanently installed lithium
battery (3 V, 1600 mAh)
• 3 years' storage
• 11 years' use
G 211001, VdS [German safety organi-
sation] 2344