Note:
The voltage detector can be used to find a break in a wire:
* To find a break in a hot conductor, trace the wire until the signal stops.
* To find a break in a neutral conductor, connect a load between the hot and
neutral. Trace the wire until the signal stops.
1.
Test the unit on known functioning circuit or component.
* If the unit does not function as expected on a known functioning circuit,
replace the batteries.
* If the unit still does not function as expected, send the unit to repair.
2.
Place the probe tip on or near the circuit or unit to be tested. Red flashing
LED indicates the presence of AC Voltage from 90 ~ 1000V AC (50/60Hz).
Note:
The voltage detector cannot detect voltage on armored cable or on cable in
conduit, behind panels, or in metallic enclosures.

5. Battery Replacement

1. Remove the end cap by gently lifting the pocket clip to release the catch.
-17-