Operational readiness period
On opening the hand-spray gun, the device
starts within the readiness period. The indi-
cator lamp glows green.
The readiness period is over if the hand-
spray gun remains closed for 30 minutes.
The indicator lamp blinks green.
Reset readiness period
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Customer Service can switch the device to
continuous operations.
Turn off the appliance
Set the appliance switch to "0".
Disconnect the mains plug from the
socket.
Shut off water supply.
Activate trigger gun until device is pres-
sure-less.
Press the safety lever of the trigger gun
to secure the lever of the pistol against
being released accidentally.
DANGER
Danger of scalding on account of hot water.
The water remaining in the switched off de-
vice can get heated up. When you remove
the hose from the water inlet, the heated
water can spray out and cause scalding. Do
not remove the hose before the device has
cooled down.
Storing the Appliance
Insert the hand-spray gun in the holder.
Wind up the high-pressure hose and
hang it over the hose storage.
or
Wind up the high-pressure hose on the
hose drum. Push in the handle of the
crank to block the hose drum.
Wind the connection cable around the
cable holder.
Frost protection
ATTENTION
Frost will destroy the not completely water
drained device.
Store the appliance in a frost free area.
If you cannot store it in a frost-free
place:
Drain water.
Pump in conventional frost protection
agents through the appliance.
Note:
Use normal glycol-based anti-freezing
agents for automobiles.
Observe handling instructions of the anti-
freeze agent manufacturer.
Operate device for max. 1 minute until
the pump and conduits are empty.
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport
it.
Pull the device behind you at the handle
for transporting it over longer distances.
When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.
This appliance must only be stored in inte-
rior rooms.
Care and maintenance
DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note:
Used oil must only be disposed of by the
designated collection points. Please turn in
used oil there. Polluting the environment
with used oil is prosecutable.
Safety inspection/ maintenance contract
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
– 5
EN
Transport
Storage
19