6. Technical data, hand wind gauge
Wind strength:
Measuring range: .............................0 to 200 km/h
Resolution: ..................................... max. 0.1 km/h
Accuracy: .................................................... ± 5 %
Temperature:
Measuring range: ............................... -20 to 70 °C
Resolution: ......................................... max. 0.1 °C
Accuracy: ...................................................... ±1 K
Measurement interval: ................................... 0.5/s
Voltage supply: ........................2 x AAA microcells
7. Short-form Operating Instructions
Hand wind gauge
- Remove protective cap carefully
(see Item 3)
- Insert batteries in accordance with Item 5
- Switch on using the "Temp" button
- Read off the measured values, measuring functions
(see Item 4)
- Automatic switch-off after 5 mins. or by holding
the "Temp" button for longer than 3 sec.
- Replace protective cap carefully
(see Item 3)