Herunterladen Inhalt Inhalt Diese Seite drucken

Pipe Connection; Supply Of Combustion Air - ADURO H2 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für H2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
Please note: that the Aduro H2 must be installed on a floor with the adequate load-bearing capacity. If the
existing construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a
load-distributing plate).
If the Aduro H2 is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the Aduro H2,
and 15 cm on each side – measured from the combustion chamber opening.

2.2 Pipe connection

Aduro H2 leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the back,
remove the round circle from the rear cover at the upper rear of the stove and then exchange the exhaust
connector (located on the top outlet above the stove) with the cover plate (that covers the rear outlet). The
top outlet is finished with the plate that lies in the ash drawer. A flue pipe with an internal diameter of 150 mm
should be used for Aduro stoves.
Aduro H2 is tested and approved for use with an uninsulated fluepipe of minimum 100 cm.

2.3 Supply of combustion air

When a stove is installed in a room, the demand for air supply in the room
raises. See point 3.9. Air from outside can be provided through a channel,
which is connected to the connecting pipe under the combustion chamber.
The amount of air needed for combustion is 25m3/h.
The connecting pipe has an external diameter of 78 mm, to which you
need a pipe with a diameter of 80 mm. If the pipe work is further than 1 m
the pipe diameter must be increased to 100 mm and a correspondingly
larger wall valve must be chosen. In warm rooms the channel should be
insulated with 30 mm mineral wool covered with a damp-proof course
(plastic). It is important that the lead-in between the pipe and the wall (or
floor) is sealed with jointing compound. You can eventually use the
complete Aduro fresh air kit.
44

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis