The wood burning stove must be installed on a floor with the adequate load-
bearing capacity. If the existing construction does not meet this requirement,
appropriate adaptation measures must be taken (e.g. a load-distributing plate).

2.2 Pipe connection

Aduro 9.7 Lux leaves the factory with the flue outlet mounted on the top. If you require the flue outlet on the
back, use a 90 flue pipe. Use a standard flue pipe, see illustration below. The top outlet is finished with the
plate that lies in the ashpan. A flue pipe with an internal diameter of 150 mm should be used for Aduro
stoves.
2.3 Connection to a brick chimney
If the stove is being connected to a brick chimney, a curved flue pipe should be used - either through the
room above the combustion chamber or through the top of the stove. After measuring, a hole is made in the
chimney in which the pipe sleeve is placed, and stove mortar is used to seal it in place. The stove is placed
in position and the flue pipe is put in place. A thin gasket is placed between the flue pipe and the pipe sleeve
to seal the joints. The flue pipe should protrude into the pipe sleeve but must not block the opening in the
chimney (see the illustration below). You may benefit from putting a slim gasket between the flue outlet on
the stove and the flue pipe.
The stove can be connected to a chimney to which other heat sources are connected.
X