4. Operation

Fan is turned on/off using a switch (e.g. light
switch). Depending on the unit variant with
start delay, with H and B units operation is
automatic or controlled with an additional
switch.
In the event of thermal overload, the unit
switches off. Wait until the motor has cooled
down. Cool-down time can be up to 10 mi-
nutes. Unit switches back on automatically
after cooling down.

5. Product information

● Small room fan for extracting air from
rooms.
● ECA 100 ipro with fixed internal grille.
● ECA 100 ipro K with electrically operated
internal shutter.
● Two performance levels as standard.
● Models
Standard: Can be operated at two levels
with an optional double switch.
Unit model
ECA 100 ipro
ECA 100 ipro VZC
ECA 100 ipro F
ECA 100 ipro H
ECA 100 ipro B
ECA 100 ipro K
ECA 100 ipro KVZC
ECA 100 ipro KF
ECA 100 ipro KH
ECA 100 ipro KB
Bold Condition as supplied
Standard equipment
4 operating programs available
with optional light switch
Start delay
Overrun time
[sec.]
[min.]
0/50/90/120
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120*
8/17/25**
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120
0/8/17/25
0/50/90/120*
8/17/25**
0/8/17/25
*
** 0 min overrun time available when using an optional
VZC and KVZC: Model with start delay
and overrun time.
F and KF: Model with light sensor, start
delay and overrun time. Switch-on intensity
(at fan) min. 30 lux. Switch-off intensity
(at fan) max. 1.7 lux.
H and KH: Model with humidity control
(fully automatic), start delay and overrun
time.
B and KB: Model with motion detector and
overrun time. Without start delay. Monito-
ring range of motion detector horizontal
100°/vertical 82°.
Humidity control function
for H and KH units
Once the fan is installed, it adjusts itself
to the prevailing room humidity (relative
humidity). This humidity value is saved as the
first reference value. The reference value
does not have to be specified manually.
If the relative humidity falls below the reference
value during operation, the newly established
reference value is saved. The lowest possible
reference value is 48 % relative humidity.
Mains cable
[mm²]
5 x 1,5
5 x 1,5
3 x 1,5
3 x 1,5
3 x 1,5
5 x 1,5
5 x 1,5
3 x 1,5
3 x 1,5
3 x 1,5
Start delay available when using an optional switch
(e.g. light switch).
switch (e.g. light switch).
4. Operation │ UK
4 operating
Speed
programmes
controllable
15